Investigated reported leak areas and plenum space within several units.
Inspected corresponding roof areas for damage and potential waterproofing issues.
Located puncture in TPO curb flashing above leak area in AT&T.
Puncture repaired using 6”TPO cover strip and lap sealant.
Located several punctures above leak area in Five Below.
Repairs made using 6” TPO covers trip and lap sealant.
Located one puncture local to leak area in Affordable dentures. Repairs made using 6”TPO cover strip and lap sealant., Located one open field seam local to leak area in Affordable Dentures.
Repairs made using 6”TPO cover strip and lap sealant., Large area in of deep ponding water removed from roof and ductwork above leak area in Five Below.
Located open termination at ductwork as well as one unsealed electrical penetration.
Sealed areas using M1 sealant.